EasyManua.ls Logo

Orolia WR-Z16 - Boundary Clock (BC VCS Code)

Orolia WR-Z16
167 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VSC HO
Device
Status
Message
Clock
Class
Active
Reference
Description
VSC-
10203
WARNING Locked:
ToD offset
bigger than
1s (NTP off-
set)
6 GM: Front-
panel
We are seeing a drift with the current
NTP offset (this is probably that NTP
server has some server, but it could be
that our external reference is in free-
running)
VSC-
10204
WARNING Locked:
NTP does
not reply
anymore
6 GM: Front-
panel
As NTP does not reply we might have
some problem with the network. This is
not critical for operation but might be a
problem at next reboot. Only the GM
should send alert
9.4.2 Boundary Clock (BC VCS Code)
A device in Boundary Clock mode is receiving its timing from a PTP/WR master and redis-
tribute to other PTP/WR slave devices.
VSC HO
Device
Status
Message
Clock
Class
Active
Reference
Description
VSC-
20001
OK Locked (TRACK_
PHASE)
6 BC: WR @
ifname
The BC clock is locked using
WR and the upstream device
provide all the information
properly set
VSC-
20001
OK Locked 6 BC: PTP
@ ifname
The BC clock is locked using
PTP and the upstream
device provide all the inform-
ation properly set
VSC-
20004
OK Locked -
Upstream in
manual Free-run-
ning
193 BC: WR @
ifname
The BC clock is locked using
WR but the upstream device
has been configured in free-
running
VSC-
20301
CRITICAL No connected ref-
erence - link
down
248 Internal
Oscillator
The BC clock has no link with
upstream device
VSC-
21301
HO CHANGEOVER Lost connected
reference - link
down
187 BC: Hol-
dover
The Link has been lost due to
a link down (VSC-20301), but
holdover was learnt (READY)
and was quickly and auto-
matically triggered
(ACTIVATED)
WR-Z16 User Manual 143
APPENDIX

Table of Contents

Related product manuals