3.1 Default Configuration
The device is factory configured with the following default settings:
Table 3-1:
Default Factory Settings
Port/ Service Default Value
eth0 Waits for DHCP offer
eth1 192.168.77.100
Timing Preset Slave on WRO (BC)
WR master on all other ports
HTTPS Disabled
SSH/web credentials
user: root
password: root
The device credentials can be configured as needed. Learn more in "Security & Authentic-
ation" on page83.
3.2 Connecting to the Device
There are two ways to connect to the WR-Z16 device using the terminal:
Via UART
Via SSH
This section will first introduce the general concepts on how to log to the device and then
it will provide the specific steps, depending on the user OS.
3.2.1 Necessary Items for Connectivity
These are the required cables and adapters:
RJ-45 Cat5/6/7 Ethernet cable.
RJ45-RS232(m) and RS232(f)-USB cable.
3.2.2 Logging from the UART
In order to connect to the WR-Z16 device, it is required to connect the RJ45-RS232(m)
and RS232(f)-USB cable to the RJ45 management port at the front panel.
Multiple software can be used to read from the UART in the computer depending on the
operating system used for that purpose (e.g. Minicom, Picocom or Putty). Learn more in
the below sections.