OID Name Value Type Description
3.7005.1 Enabled <Boolean>
• YES
• NO
If ‘Yes’ the device will act as an NTP server on its
management interfaces to distribute its own Time
of Day to other devices.
3.7005.4 Stratum Mode • Auto
• Manual
Mode to provide the NTP stratum. If Manual it will
directly set the value from ‘Manual Stratum’, oth-
erwise it will take into account the virtual clock qual-
ity (timing source, clock accuracy, etc.) to modify
this value.
3.7005.7 Manual
Stratum
• Stratum 1
• Stratum 2
• Stratum 3
• Stratum 3E
• Stratum 4
• Stratum 4E
• Stratum 15
Manually force the Stratum announced by the NTP
server. See
"Stratum Levels" on the facing
page
for more information
Caution: Reboot to apply NTP provider parameter: Many of the settings to
configure the NTP server are only loaded during initialization of the device
and thus a reboot might be needed in order to apply them.
5.6.1.2 NTP Timing Source Configuration
The configuration of an NTP timing source is divided in two parts. The first panel provides
the configuration shared by all the NTP timing sources:
OID Name Value Type Description
3.7001.x ntp/cfg/xxx Configuration on how to provides NTP to
3rd party devices.
.
3.7001.2 Refresh
Rate
<Integer>
• Default: 30
Time lapse between NTP server queries (in seconds).
3.7001.3 Retries <Integer>
• Default: 5
Number of retries for NTP server queries performed at
the initialization of the device.
The second panel is a table where each column represents an NTP timing source:
OID Name
Value
Type
Description
3.70x0.x
ntp/x/cfg/xxx Configuration of the x NTP timing source (x=[1-
5]).
3.70x0.0 IPv4
Server
<String> IP or URL of the reference NTP server.
76
CHAPTER 5 • WR-Z16 User Manual Rev. v3.4