OID Name Value Description
3.13x0.2 Type GM
WR
PTP
HO/FR
Type of timing source, each type can have slightly different
state machines to properly handle its timing source.
3.13x0.3 VCS
Code
<Integer> Code defined in the VSC table (
"VCS Code" on
page141
) that corresponds to a given condition for this
timing source.
3.13x0.4 Status Disabled
OK
Warning
Critical
Status that corresponds to the code defined in the VSC
table.
3.13x0.6 Is Act-
ive
<Boolean> Flag that indicates if this timing source has been selected
by the policy to actively discipline the virtual clock of our
device.
The timing source can be expanded to show its advanced view by clicking on the (+) but-
ton:
Figure 5-11: Advanced info Timing Source #1
The advanced view parameters are described below:
Table 5-1:
Timing source info description
OID Name Value Description
3.13x0.xx
tsrc_info/x/xxx
Information about the x timing source.
3.13x0.5 Message <String> Message that corresponds to the code defined in the VCS table.
3.13x1.xx
tsrc_info/x/Q Clock Quality of the x timing source.
3.13x1.1 Clock
Identity
<String> Unique identity of PTP instance in the network.
5.2 General Timing Management