OID Name Value Type Description
19.xx12.x net/<iface>/1/info Information on the corresponding
<iface> port instance
.
19.xx12.2 Port State <Enum>
0. None
1. Initializing
2. Faulty
3. Disabled
4. Listening
5. Pre-Master
6. Master
7. Passive
8. Uncalibrated
9. Slave
Current state of the port that changes according
to the PTP protocol events.
• If this port is configured as a timing source, it
can be Slave (active) or Passive (only handle
announce messages) à Color: Blue.
• The port state is Disabled when the link is
down or when the port has been configured
with WR instead of PTP.
• The port state will be Master if it distributes
PTP timing (Color: Purple).
Finally, the other states are transition states
(mainly used by BMCA) or error states.
19.xx12.3 Clock State <Enum>
0. Idle
1. Locking
2. Error
3. Locked to Ref
4. Free-running
State of the clock (internal oscillator) shared by
all PTP instances. “Locked to Ref” is the desired
stated.