Figure 5-18: wr0 port as active PTP slave with its advanced view expanded.
Table 5-3:
PTP information for a port interface
OID Name Value Type Description
19.xx12.x net/<iface>/1/info Information on the corresponding
<iface> port instance
.
19.xx12.2 Port State <Enum>
0. None
1. Initializing
2. Faulty
3. Disabled
4. Listening
5. Pre-Master
6. Master
7. Passive
8. Uncalibrated
9. Slave
Current state of the port that changes according
to the PTP protocol events.
If this port is configured as a timing source, it
can be Slave (active) or Passive (only handle
announce messages) à Color: Blue.
The port state is Disabled when the link is
down or when the port has been configured
with WR instead of PTP.
The port state will be Master if it distributes
PTP timing (Color: Purple).
Finally, the other states are transition states
(mainly used by BMCA) or error states.
19.xx12.3 Clock State <Enum>
0. Idle
1. Locking
2. Error
3. Locked to Ref
4. Free-running
State of the clock (internal oscillator) shared by
all PTP instances. Locked to Ref” is the desired
stated.
70
CHAPTER 5 WR-Z16 User Manual Rev. v3.4
5.4 IEEE 1588-2008 (PTPv2)

Table of Contents