12. Emergency Operation
21
(EN)
ENGLISH
Use [Emergency Operation] in the following situations when there is an urgent need.
When the remote controller’s batteries have failed.
When the remote controller is broken.
When the remote controller is lost.
*
1
Figures: CZ-RWSU2N, CZ-RWSD2, and CZ-RWST3N are of receivers
(inside indoor unit), CZ-RWSL2N is of the operation panel (inside indoor
unit) and indoor unit (CZ-RWSK2) is of its front panel.
CZ-RWSU2N/CZ-RWSD2/Indoor Unit (CZ-RWSK2)/CZ-RWST3N
CZ-RWSL2/CZ-RWSC3
Start: press [Emergency Operation]
of the receiver.
If the indoor temperature is 24 °C or greater when the unit starts running, it
will act as a cooler.
If the indoor temperature is less than 24 °C when the unit starts running, it
will act as a heater.
Stop: press [Emergency Operation] of the receiver again.
CZ-RWSD2
Start/Stop
Start/Stop
CZ-RWSU2N
CZ-RWST3N
Start/Stop
Start/Stop
Start/Stop
Start/Stop
Start/Stop
TIMEROPERATION
STANDBY
CZ-RWSL2N CZ-RWSC3
00OI303000.indb21 2015/02/2016:23:08
20
(EN)
Wireless
remote
controller
address
display
•••••
Address
switch
position
Address Address Address Address Address Address Address
ALL
1234
5
6
Receiving is
possible at all
address
positions
㻻㻲㻲
㻻㻺
㻻㻲㻲
㻻㻺
㻻㻲㻲
㻻㻺
㻻㻲㻲
㻻㻺
㻻㻲㻲
㻻㻺
㻻㻲㻲
㻻㻺
Setting Addresses (CZ-RWSK2)
(Setting the address of the indoor unit)
1. Set the address for the remote controller following the
procedure under the section “Setting Remote Controller
Addresses” (see page 19).
2. Press [Emergency Operation]
of the indoor unit for four
seconds or longer.
When you do this, the lamps of the display will blink one after another.
3. Press on the remote controller.
4. The buzzer will sound and the address of the indoor unit will
change to the address displayed on the remote controller.
5. If you press [Emergency Operation]
of the indoor unit once,
the lamps on the indoor unit’s display will turn off.
Notes
Please do not hold the [Emergency Operation] button of the indoor unit down
while the indoor unit’s display lamps are blinking one after another.
Make sure to operate while the indoor unit is stopped.
The address of indoor unit is set to "ALL" at the time of the shipment.
11. Addresses (Cont.)
ON
OFF
Interruptor
ON/OFF
00OI303000.indb20 2015/02/2016:23:07
SM830241-00_2WAY SYS.indb 37 2015/03/26 14:55:13

Table of Contents

Other manuals for Panasonic CZ-RTC4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CZ-RTC4 and is the answer not in the manual?

Panasonic CZ-RTC4 Specifications

General IconGeneral
BrandPanasonic
ModelCZ-RTC4
CategoryRemote Control
LanguageEnglish

Related product manuals