SET-UP PARAMETERS
PREF 6511/6901
Display
Default Brief Description V/Hz
SV Vector
Required parameters for each control mode are shown shaded.
4.03
AIN4 TYPE
0 : -10..+10 V
1 : 0..+10 V
2 : 0..20 mA
3 : 4..20 mA
Select the input range
and type
x x x
97.01
DISABLE TRIPS
0700 >> Indicates which trips
have been disabled -
refer to Chapter 10
x x x
97.02
DISABLE TRIPS +
0840 >> Indicates which trips
have been disabled -
refer to Chapter 10
x x x