890CS & 890CD Common Bus Units
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D Page 4-39
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
8
9
1
2
3
4
5
6
E
The following is a list of the Set-up parameters you may need to check before starting the drive. Set only
the ones marked with "x" for the intended mode of operation.
Note Parameters whose values are "product code dependent" will have a typical value for the size of unit.
Where possible (or required), enter an application -specific value for improved performance, otherwise
use the typical value.
Note "PREF" is a parameter reference number used by the DSE 890 Configuration Tool.
SET-UP PARAMETERS
PREF 6511/6901
Display
Default Brief Description V/Hz
SV Vector
Required parameters for each control mode are shown shaded.
27.01
CONTROL
MODE
0 : VOLTS / HZ
1 : SENSORLESS VEC
2 : CLOSED-LOOP VEC
Select the operating
mode for the drive.
x
(0)
x
(1)
x
(2)
101.08
MAX SPEED
product code dependent The maximum speed
clamp and scale factor
for other speed
parameters (at full
process speed)
x x x
100.02
RAMP ACCEL
TIME
10.0 s Acceleration time from
0 rpm to MAX SPEED
x x x
100.03
RAMP DECEL
TIME
10.0 s Deceleration time from
MAX SPEED to 0 rpm
x x x