SET-UP PARAMETERS
PREF 6511/6901
Display
Default Brief Description V/Hz
SV Vector
Required parameters for each control mode are shown shaded.
21.03
FIXED BOOST
product code dependent Boosts starting torque
by adding volts at low
speed
x
82.01
CURRENT LIMIT
150.00% Level of motor current
as % of FULL LOAD
CALIB
x x x
27.03
MOTOR BASE
FREQUENCY
product code dependent Enter the motor
nameplate base
frequency
x x x
27.04
MOTOR
VOLTAGE
product code dependent Enter the motor
nameplate voltage at
base frequency
x x x
27.07
NAMEPLATE RPM
product code dependent Enter the motor
nameplate full-load
rated speed. This is the
motor speed in rpm at
base frequency minus
full load slip.
x x x