Installer Manual Fleck 5810 - SXT - Programming
Ref. MKT-IM-016 / C - 08.06.2018 57 / 106
CT
Regeneration
control type
Fd Meter delayed
FI Meter immediate
tc Time clock
dAY Day of the week
C Unit capacity 1 to 999’900
°TH*L
g as CaCO
3
Only displayed for volumetric
regenerations.
V Filter capacity 1 to 999’900 L Only displayed for filter.
H
Feedwater
hardness
1 to 1999 °TH, ppm
Only displayed for volumetric
regenerations.
RS
Reserve
selection
SF Safety factor
rc
Fixed reserve
capacity
Only displayed for meter delayed and
immediate regenerations.
cr
Variable reserve
capacity
Only displayed for meter delayed
regenerations.
SF Safety factor 0 to 50 %
Only displayed if set in reserve
selection.
RC
Fixed reserve
capacity
0 to half of
the volume
capacity
L
DO Days override OFF to 99 Day
Not displayed for "Day of week"
regeneration.
RT
Regeneration
time
00:00 to
23:59
Hour
In case of volumetric immediate
regeneration, only displayed if DO is
ON.
B1 First backwash
0 to 199 Minute
Only displayed for dF2b regeneration
flow.
B2
Second
backwash
BD Brine draw
BF Brine fill
BW Backwash
Parameter Options Definition Note