Installer Manual Fleck 5810 - SXT - Programming
58 / 106 Ref. MKT-IM-016 / C - 08.06.2018
LC Last cycle
0 to 199 Minute
Only displayed for O-dF and O-UF
regeneration flows.
RF Refill
RR Rapid rinse
SP Service position
Only displayed for O-dF and O-UF
regeneration flows.
SR Slow rinse
SV
Brine
preparation
Only displayed for "UFFF"
regeneration flow.
Cn
Cycle number,
n=1 to 20
BD, BW, RF,
RR, SP, SR,
LC
-
Only displayed for O-dF and O-UF
regeneration flows.
Dn
Day of week,
n=1 to 7
On - OFF -
Only displayed for day of the week
regeneration. OFF by default.
CD Current day 1 to 7 Day of the week
Only displayed for day of the week
regeneration.
FM Flow meter type
P0.7 ¾" paddle wheel
Only displayed for volumetric
regeneration.
t0.7 ¾" turbine
P1.0 1" paddle wheel
t1.0 1" turbine
t1.2 1¼" turbine
P1.5 1½" paddle wheel
t1.5 1½" turbine
P2.0 2" paddle wheel
Gen
Generic or
non-Fleck
K Meter pulse 0.1 to 999.9 Pulse/Litre Only displayed for generic flow meter.
RE
Time based relay
setting
OFF - tb Time based
ST Relay start time
0 to the total
of
regeneration
duration
minus 1
Minute Only displayed for tb relay setting.
Parameter Options Definition Note