76700 -52/94-
20. [Confirm] Function check 2
[Required equipment] CF card 2pcs (for SW testing and Taking picture), Battery adaptor,
Regulated DC power supply (8V/3A), DC cord, Circuit tester, Lens for checking (FA50mmF1.4), Cable switch
CS-205, remote control F, Flash for checking (AF360FGZ etc)
20-1. Preparation
(1) Temporarily install the bottom cover and
battery cover for battery adaptor by 2 screws.
20-2. Battery consumption
[Caution]If there is overcurrent, disconnect the power immediately.
(1) Connect battery adaptor to the power supply and then set DC 5.6V (3A).
(2) Set the battery adaptor to the camera and confirm the battery consumption current.
There must be neither short nor leakage.
*Refer to [Information of Jigs, tools…..] for usage battery adaptor.
(3) Remove battery adaptor and put battery cover again.
(4) Connect the DC code to the power supply and set DC5.6V.
(5) Connect the DC code to the camera, confirm the battery consumption current.
There must be neither short nor leakage.
20-3. AF and SI Check
(1) Attach the lens to the camera and set the AF_SW to AF.
(2) Check auto focus function while pressing the release button halfway.
(3) Confirm the display of SI (Superimpose) in the viewfinder.
20-4. Exposure mode, release function
(1) Attach the lens to the camera and set the AF_SW to MF
(2) Set the mode dial to P
(3) TV, AV data should be display on the LCD and viewfinder when
press shutter button halfway
(4) Confirm the display on the LCD and viewfinder while changing the mode dial.
(5) Attach cable switch to the camera, and then check the shutter release function.
(6) Set remote control mode by Fn button, and check the release function using remote control.
At the same time, you will hear the beep.
(With default setting. If selected beep off on the main menu, camera won’t beep)
Consumption currentAverage Battery power AC powerDC6.5V
Main SW/OFF 50µA 10mA
Main SW/ON --- Light metering OFF 180mA 240mA
Light metering ON 370mA 420mA
Auto power off condition 250µA 10mA