76700 -76/94-
(10) Confirm the camera in focus on chart.
[Supplement] If focus is NG, There is possibility with following factors.
AF focus position error or adjusting error. (Confirm AF focus position (FI) : NG)
Adjust positioning of 1
st
and 2
nd
Mirror, AF adjustment by programmed software (Part of SLR
mechanism)
Height of the CCD Base Plate Support Pillar is NG
Confirm with disassembly, Adjust with washer and re-assemble.
Related parts: Mount ring, Front, Front Housing Block, body main plate (pillar installing parts), and other
frame (0-A3, A4, A5,A6)
If camera is OK, There is possibility for trouble with the lens.
26-6Confirmation of SR mechanism
Preparation: Personal computer, AC adaptor, USB cable, FA50mm lens, SD card(For test), Application
software
(PENTAX PHTO Browser
TM
ACDSee
TM
Adobe Photoshop)
Attach FA50mm lens to the camera and set aperture ring at A position.
Set the camera as follow
Exposure Tv mode, AF focus mode, AF measurement --- Center, AF.S mode
Drive mode --- Single, AWB (Fn menu), Recording size --- 6M ***
Set Tv15 (1/15sec) --- It is equal to approx 2.5 step
The distance of the camera is set from subject to 2m.
Set the SR switch to OFF and capture 10 images. ( Camera is set on Horizontal position)
Set the SR switch to ON and capture 10 images. ( Camera is set on Horizontal position)
[Caution] Release the shutter about 1 second later after hand shake indication is ON in the view finder
Open the image with application soft
Compare the images (SR ON/ SR OFF) and confirm that whether SR function is effective
30°

Table of Contents