3
L
1
L
2
5.2 5.1 5.75.6
5.4 5.5 5.65.3 5.7
5.8
CB 240 Climbing Formwork
Instructions for Assembly and Use – Standard Configuration
Introduction
Anchoring to the building structure
Version 1
5.4 Threaded Anchor Plate DW 15*
5.5 Tie Rod DW 15*, Z-12.4-70
L
1
= h – 8 cm or Tie Rod B15*, Z-12.5-82
5.3 Climbing Cone 2 M24/DW 15
5.6 Scaffold Mounting Ring M24, galv.
5.7 Hex. Bolt M24 x 120 ISO 4014-10.9
5.8 Spacer Tube DR 22* (optional)
L
2
= h – 18.5 cm (tolerance 0 to +5 mm)
Anchoring depth h ≥ 18.5 cm (variable).
* “Not re-usable
When using the PVC Spacer Tube, the
tie rod (5.5) can be re-used.
Version 2
5.2 Threaded Anchor Plate DW 20*
5.1 Screw-On Cone 2 M24/DW 20
5.6 Scaffold Mounting Ring M24, galv.
5.7 Hex. Bolt M24 x 120 ISO 4014-10.9
Anchoring depth h = 15.5 cm (fix).
* “Not re-usable
Overview, Main Components
15,5 cm
Ø 10 cm
h
Ø 8 cm
AuV CB 240 EX.indb 3 29.06.16 09:44