Technical data and ordering data
107065_en_01 PHOENIX CONTACT 81
11.4 Technical data for devices in the 2300 version
Mechanical tests
Shock testing according to IEC 60068-2-27 Operation: 30g,
half-sine shock pulse
Vibration resistance according to IEC 60068-2-6 Operation/storage/transport: 5g, 10 Hz - 150 Hz
Free fall according to IEC 60068-2-32 1 m
Conformance with EMC Directives
Developed according to IEC 61000-6-2
Noise emission according to EN 55022: 1998
+ A1: 2000 + A2: 2003 (interference voltage)
Class A (industrial applications)
Noise emission according to EN 55011: 1998
+ A1: 1999 + A2: 2002 (electromagnetic interference)
Class A (industrial applications)
Noise immunity according to EN 61000-4-2 (IEC 1000-4-2) (ESD)
Contact discharge:
Air discharge:
Indirect discharge:
Requirements according to DIN EN 61000-6-2
Test intensity 3, criterion B
Test intensity 3, criterion A
Test intensity 3, criterion A
Noise immunity according to EN 61000-4-3 (IEC 1000-4-3)
(electromagnetic fields)
Requirements according to DIN EN 61000-6-2
Test intensity 3, criterion A
Noise immunity according to EN 61000-4-6 (IEC 1000-4-6) (conducted) Requirements according to DIN EN 61000-6-2
Test intensity 3, criterion A
Noise immunity according to EN 61000-4-4 (IEC 1000-4-4) (burst)
Data cables:
Power supply:
Requirements according to DIN EN 61000-6-2
Test intensity 3, criterion A
Test intensity 3, criterion A
Noise immunity according to EN 61000-4-5 (IEC 1000-4-5) (surge)
Data cables:
Power supply:
Requirements according to DIN EN 61000-6-2
Test intensity 2, criterion A
Test intensity 1, criterion A
Additional certifications
RoHS @EEE 2002/95/EC - WEEE 2002/96/EC
IECEx:
IEC 60079-0:2011, 6
th
Edition
IEC 60079-15:2010, 4
th
Edition
ATEX:
EN 60079-0:2012+A11:2013
EN 60079-15:2010
Field of application:
II 3 G Ex nA IIC T4 Gc
IECEx ULD 16.0018X
General data
Function Ethernet/Fast Ethernet/Gigabit Switch; conforms to standard
IEEE 802.3/802.3u/802.3ab
Switch principle Store and forward
Address table 8192 MAC addresses