Item Function
BT 13
Has two functions.
Out of cycle: Controls coolant pump and gas 1
and 2 fl ow rates.
In cycle: Stops cycle manually with slope-
down.
BT 14
Push button “Start cycle with restart”.
BT 15
Push button "Start cycle".
BT 16
Push button "Stop cycle immediately".
BT 18
Has two functions.
Out of cycle: Raise torch.
In cycle: Increment torch height.
BT 19
Has two functions.
Out of cycle: Lower torch.
In cycle: Decrement torch height.
BT 20
Toggles between:
Suspension of the AVC ( - V 10 illuminated).
Running of the AVC ( - V 9 illuminated).
Function not available
Item Function
BT 21
Pushbutton to toggle between the following
overrides:
In amplitude "A" ( - V 7 illuminated).
In time "T" ( - V 8 illuminated).
BT 22
Has two functions.
Out of cycle: torch oscillation with self-cen-
tring.
In cycle: Decreases the oscillation in amplitude
or in time according to BT 21.
BT 23
Has two functions.
Out of cycle: no action.
In cycle: Increases the oscillation in amplitude
or in time according to BT 21.
BT 24
Push button to off-set torch to the left.
BT 25
Push button to off-set torch to the right.
BT 26
In cycle: Increases the "hot wire" current
BT 27
In cycle: Decreases the "hot wire" current
BT 28
Toggles between:
Suspension of "hot wire" current (indicator -
light V 12 lit).
Operation of "hot wire" current (indicator light -
V 11 lit).
Using the remote control to regulate the AVC4. 4. 4.
Remote control
Programmed regulation Override mode AVC + AVC -
Smooth voltage
High
U + U -
Low
U + U -
High and low
U + U -
High voltage
High
Uh + Uh -
Low --
High and low
--
Low voltage
High
--
Low
Ul + Ul -
High and low --
High and low voltage
High
Uh + Uh -
Low
Ul + Ul -
High and low
Uh +
Ul +
Uh -
Ul -