List of programmed welding parameters7. 3.
Gas axis
Function Wording Ref. Min. Max. Unit Increment Default
Prepurge time Pregas time T10 1,0 999,0 s 0,1 10,0
Postpurge time Postgas time T11 1,0 999,0 s 0,1 10,0
Oxygen ow rate control
Oxygen
threshold
L10 1,0 206400 ppm 0,1 50,0
Current axis
Function Wording Ref. Min. Max. Unit Increment Default
Ignition current Ignition current I20 5 520 A 1 25
Prefusion ramp time Ramp time T20 0 9999 s 1 0
High current High current I22 5,0 520.0 A 0,1 10
High current time Pulse time high T22 0 ou 10 3000 ms 1 100
Low current Low current I23 5,0 520.0 A 0,1 5
Low current time Pulse time low T23 0 ou 10 3000 ms 1 100
Start of downslope Start downslope N20 361 9999 ° 1 365
Downslope time Downslope time T25 0,1 60,0 s 0,1 3,0
Arc cut-off current
Arc cut-off cur-
rent
I25 5 520 A 1 5
Hot-wire leadtime
Hot-wire lead-
time
T27 0,0 60,0 s 0,1 3,0