VAC4 and VAC4S Hardware User’s Guide
35-Idle Motion Error (Refer to Hardware Guide)
[SHUTDOWN] The VAC has detected an idle threshold that is not within the specified range of 20.
Insufficient “BLU”
(motion sensing)
connection point
• Verify that the “BLU” wire is connected to the proper traction (motion) sensing circuit.
Refer to the PowerFleet
®
Installation Guide.
• Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2)
Failed fuse on “BLU”
(motion sensing) wire
• Verify that the fuse for the “BLU” wire is not blown or missing.
• Repair as needed.
• Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2)
“BRN” wire connection
point (Internal
combustion vehicles
only)
• Verify that the “BRN” wire is connected to the proper traction (motion) sensing circuit.
Refer to the PowerFleet
®
Installation Guide.
• Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2)
Incorrect idle motion
values
• Log in to the VAC as a Maintenance operator and re-run the configuration wizard
(see Section 2).
• Log in to the VAC and review the motion values (see: “Defining ‘Motion’ Manually”).
• Adjust values as needed.
• Use an ohmmeter to check resistance to verify cable integrity (an “open” or zero
reading indicates a damaged cable) on the “BLU” and “BRN” wires.
• Replace the cable as needed and retest.