TECHNICAL INFORMATION
MAIN
CODE
SUB
CODE
DESCRIPTION
CHECK
TRANS
LIGHT
INHIBITED OPERATION
DESCRIPTION
25 66
Output speed sensor detected at 0
speed (6th)
Yes
(1)
DNS, lock in current range
(6th), DNA
25 77
Output speed sensor detected at 0
speed (R)
Yes
(1)
DNS, lock in current range
(R), DNA
26 00 Throttle source not detected No
Use throttle default values,
DNA
26
11
Engine coolant source not detected
No
Use default value of 0°F
32 0 C3 pressure switch open, Low range Yes
DNS, lock in current range
(Low), DNA
32 33 C3 pressure switch open, 3rd range Yes
DNS, lock in current range
(3rd), DNA
32 55 C3 pressure switch open, 5th range Yes
DNS, lock in current range
(5th), DNA
32 77
C3 pressure switch open, Reverse
range
Yes
DNS, lock in current range
(R), DNA
33 12
Sump oil temperature sensor failed
low
No
Use default value of 200°F
(93°C)
33 23
Sump oil temperature sensor, failed
high
No
Use default value of 200°F
(93°C)
34 12
Factory calibration compatibility
number wrong
Yes
DNS, SOL OFF (Hydraulic
default), DNA
34 13 Factory calibration block checksum Yes
DNS, SOL OFF
(Hydraulic default), DNA
34 14 Power off block checksum No
Use previous location or
factory calibration and reset
adaptive, DNA
34 15 Diagnostic queue block checksum No
Use previous location or clear
diagnostic queue, DNA
34 16 Real time block checksum Yes
DNS, SOL OFF
(Hydraulic default), DNA
34 17
Customer modifiable constants
checksum
Yes
DNS, SOL OFF
(Hydraulic default), DNA
35 0
Power interruption (code set after
power restored)
No
None (Hydraulic default
during interruption)
35 16 Real time write interruption Yes
DNS, SOL OFF
(Hydraulic default), DNA
36 0 Hardware/Software not compatible
Yes
(2)
DNS, SOL OFF
(Hydraulic default), DNA
42
12
Short to battery, A solenoid circuit
Yes
DNS, SOL OFF, DNA
42
13
Short to battery, B solenoid circuit
Yes
DNS, SOL OFF, DNA
42
14
Short to battery, C solenoid circuit
Yes
DNS, SOL OFF, DNA
42
15
Short to battery, D solenoid circuit
Yes
DNS, SOL OFF, DNA
42
16
Short to battery, E solenoid circuit
Yes
DNS, SOL OFF, DNA
42
21
Short to battery, F solenoid circuit
No
Lock up inhibited, DNA
42
22
Short to battery, G solenoid circuit
Yes
DNS, lock in a range
42 23 Short to battery, H solenoid circuit No
Differential lock inhibited
(3070 only), retarder inhibited
42
24
Short to battery, J solenoid circuit
No
Low and 1st inhibited
42 26 Short to battery, N solenoid circuit No
Low and 1st inhibited, allow
retarder
44 12 Short to ground, A solenoid circuit Yes
DNS, SOL OFF
(Hydraulic default), DNA
128