EasyManua.ls Logo

PREVOST H3-41 - Page 136

PREVOST H3-41
151 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TECHNICAL INFORMATION
MAIN
CODE
SUB
CODE
DESCRIPTION
CHECK
TRANS
LIGHT
INHIBITED OPERATION
DESCRIPTION
44 13 Short to ground, B solenoid circuit Yes
DNS, SOL OFF
(Hydraulic default), DNA
44 14 Short to ground, C solenoid circuit Yes
DNS, SOL OFF
(Hydraulic default), DNA
44 15 Short to ground, D solenoid circuit Yes
DNS, SOL OFF
(Hydraulic default), DNA
44 16 Short to ground, E solenoid circuit Yes
DNS, SOL OFF
(Hydraulic default), DNA
44
21
Short to ground, F solenoid circuit
No
Lockup inhibited, DNA
44 22 Short to ground, G solenoid circuit Yes
DNS, SOL OFF
(Hydraulic default), DNA
44 23 Short to ground, H solenoid circuit No
Differential lock inhibited
(3070 only), retarder
operation inhibited
44
24
Short to ground, J solenoid circuit
No
Low and 1st inhibited
44 26 Short to ground, N solenoid circuit No
Low and 1st inhibited,
retarder allowed
45 12 Open circuit, A solenoid circuit Yes
DNS, SOL OFF
(Hydraulic default), DNA
45 13 Open circuit, B solenoid circuit Yes
DNS, SOL OFF
(Hydraulic default), DNA
45 14 Open circuit, C solenoid circuit Yes
DNS, SOL OFF
(Hydraulic default), DNA
45 15 Open circuit, D solenoid circuit Yes
DNS, SOL OFF
(Hydraulic default), DNA
45 16 Open circuit, E solenoid circuit Yes
DNS, SOL OFF
(Hydraulic default), DNA
45
21
Open circuit, F solenoid circuit
No
Lock up inhibited, DNA
45 22 Open circuit, G solenoid circuit Yes
DNS, SOL OFF
(Hydraulic default), DNA
45 23 Open circuit, H solenoid circuit No
Differential lock inhibited
(3070 only), retarder inhibited
45
24
Open circuit, J solenoid circuit
No
Low and 1st inhibited
45 26 Open circuit, N solenoid circuit No
Low and 1st inhibited,
retarder allowed
46
21
Overcurrent, F solenoid circuit
No
Lock up inhibited, DNA
46 26 Overcurrent, N and H solenoid circuits No
Low and first inhibited or
retarder inhibited, DNA
46 27 Overcurrent, A-Hi solenoid circuit Yes
DNS, SOL OFF
(Hydraulic default), DNA
51 01
Offgoing ratio test (during shift), Low
to 1
Yes DNS, RPR, DNA
51 10
Offgoing ratio test (during shift), 1 to
Low
Yes DNS, RPR, DNA
51
12
Offgoing ratio test (during shift), 1 to 2
Yes
DNS, RPR, DNA
51
21
Offgoing ratio test (during shift), 2 to 1
Yes
DNS, RPR, DNA
51
23
Offgoing ratio test (during shift), 2 to 3
Yes
DNS, RPR, DNA
51
24
Offgoing ratio test (during shift), 2 to 4
Yes
DNS, RPR, DNA
51
35
Offgoing ratio test (during shift), 3 to 5
Yes
DNS, RPR, DNA
51
42
Offgoing ratio test (during shift), 4 to 2
Yes
DNS, RPR, DNA
51
43
Offgoing ratio test (during shift), 4 to 3
Yes
(1)