Page #76 background imageLoading...
Page #76 background image
Modul
e/slot
Index Name Module
name
Diag.
numb
er
Identi‐
fication
(hex)
Type Data‐
flow *
Description
29 -
30 -
31 -
2 Warn‐
ings
19 u16 Bit Name Function
0 Min‐
imum
Metering liquid
is low
1 Calibra‐
tion
-
2 Dosing
monitor
Metering moni‐
toring warning
3 Dia‐
phragm
rupture
Defective dia‐
phragm in the
dosing head
4 Airlock Air in dosing‐
head
5 -
6 Cavita‐
tion
7 Over‐
pres‐
sure
Overpressure
in hydraulics
8 Low
pres‐
sure
Pressure too
low in
hydraulics
9 -
10 -
11 -
12 -
13 -
14 -
15 -
* R = read, W = write
Supplementary Operating Instructions PROFIBUS
®
76

Table of Contents

Other manuals for ProMinent gamma/ X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent gamma/ X and is the answer not in the manual?

ProMinent gamma/ X Specifications

General IconGeneral
Protection classIP65
Max. Pressure25 bar
Power supply100-230 V, 50/60 Hz
Material of pump headPVDF, Stainless steel
Temperature range-10 °C to +45 °C
TypeDiaphragm dosing pump
Stroke lengthAdjustable
Stroke frequencymax. 180 strokes/min
Materials in contact with the mediumPVDF, PTFE, stainless steel
ControlManual, external control via contacts or 0/4-20 mA signal
Control OptionsExternal, potential-free contacts, 0/4-20 mA
Dosing Accuracy±2%