9.2 Appendix B – Systems Set-Up Documents
9.2.1 To set up a Mitsubishi D700 inverter (Ref MAP009)
Prior to commissioning or following component replacement it will be necessary to set up the
inverter. Working through the following procedure will set up the inverters.
Connect the motor and other ancillary cabling.
Ensure that the inverter is powered up – the safety interlock must be engaged.
Press the ‘Run Stop’ button to ensure that the inverter is not running.
Press the ‘Mode’ key to enter parameterisation mode ‘P 0’ is displayed.
Turn the dial until desired parameter appears, press the ‘Set’ key to show present setting, turn the
setting dial to change value and Press the ‘Set’ button to complete setting.
When all parameters are set, press the mode button until ‘0.00’ is displayed.
Using the tables found in the specific manual, set the listed parameters. Once completed run the
inverter at the various required speeds and acceleration/deceleration profiles. Ensure smooth
movement throughout the speed range.