GTR-3455
Doc Ref: Page: 53
Date: 13/01/13 Issue: H
Pr
seal
®
uk
Tray Sealing Solutions
9.2.3 To set up a reg film sensor (Ref MAP011)
Ensure that the two dipswitches (under the sensor cover) are set as follows on the registered film
sensor and on the print sensor. The dipswitches are set by the manufacturer before delivery to
Proseal.
ON
OFF
1.1 Place registration mark beneath the sensor
1.2 Push button labelled mark for 2 seconds then release
1.3 Place background beneath the sensor
Push button labelled background for 2 seconds then release