Q40 Tape Library Installation and Operations Manual
511026 Rev. 07-01-19 172
T
able 29: Regulatory Specifications (CSA test conditions)
Tested condition or value
Equipment mobility
Stationary - rack mount
Connection to the mains
Pluggable - Type A
Operating condition
Continuous
Access location
Operator accessible
Over voltage category (OVC)
OVCII
Mains supply tolerance (%) or absolute
mains supply values
-10%, +6%
Tested for IT power systems
No
IT testing, phase-phase voltage (V)
N/A
Class of equipment
Class I
Considered current rating (A)
20 A (branch circuit protection)
Pollution degree (PD) PD 2
IP protection class IPXO
Altitude during operation (m) Max 2000
Altitude of test laboratory (m) 38
Mass of equipment (kg) Max 25 kg
Manufacturer's Declared Ambient (0C) 40°C
NOTE
The CSA test conditions might differ from the product
specification limits.