EasyManua.ls Logo

R&S EB200 - Page 171

R&S EB200
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EB200 Manual STATus subsystem
4052.2000.02 4.97 E-7
Exemplifying all STATus register commands, for example the STATus:OPERation:SWEeping register,
the commands of the STATus:OPERation register are explained as follows.
STATus
. OPERation
. . :CONDition?
Query of the condition section of the OPERation status register
Parameters:
none
Result:
Depending on the setting by the FORMat:SREGister command, the contents of the register is
transferred as a decimal, binary or hexadecimal value in the ASCII code.
Example:
STATus:OPERation:CONDition? -> #H0008
. . :ENABle <numeric_value>
Setting the enable section of the OPERation status register
Parameters:
<numeric_value> value of the enable section (0..65535 or #H0000..#HFFFF
or #B0..#B1111111111111111)
*RST state:
will not be changed by *RST
Example:
STATus:OPERation:ENABle #H0008
. . :ENABle?
Query of the enable section of the OPERation status register
Parameters:
none
Result:
Depending on the setting by the FORMat:SREGister command, the contents of the register is
transferred in decimal, binary or hexadecimal form in the ASCII code.
Example:
STATus:OPERation:ENABle? -> #H0008

Table of Contents