EB200 Manual Operation
4052.2000.02 3.56 E-7
3.18.6.6 REMOTE (remote control)
Configuration of the remote-control parameters
This menu is obtained by pressing the REMOTE softkey in the SETUP menu.
One of the two options below can be fitted:
RS232C control interface
LAN control interface
The appropriate window for the fitted option opens automatically.
After a cold start, the Rohde & Schwarz default values are always used.
LAN control interface (option)
Configuration parameters
IP ADDRESS: Network ident of EB200
PORT: Remote control port
SUBNETMASK: Mask for a subnet
GATEWAY: Network indent of a router
Softkey
APPLY: Branching to subsequent submenu
APPLY CHANGES
Some parameters can be made active only by switching the unit off and on again. After confirmation the
changes to such parameters with the YES key, the following warning is output: POWER DOWN
REQUIRED FOR NEW SETTINGS.
YES: The changes are accepted. For some parameters the unit must be switched off and
on again.
NO: The changes are discarded.