EB200 Manual Operation
4052.2000.02 3.54 E-7
3.18.6.3 POWER
This menu is used to display all parameters of the DC power supply which might be connected.
This menu is obtained by pressing the POWER softkey in the SETUP menu.
Configuration parameters
SOURCE: Power source:
DC X1 DC power supply or charger
BATTERY PACK EB200 Battery Pack
DC X2 Battery belt
BATTERY1 / 2: Status of battery 1 / 2: NOT EQUIPPED
NOT IN USE
IN USE
CHARGING
TIME TO EMPTY: Display of remaining service time in minutes (overall service time of batteries 1
and 2)
The display is only active for supply from the battery pack.
When the remaining service time has come down to 10 min, the warning "BATTERY EMPTY IN LESS
THAN 10 MINUTES" comes up in a cyclic fashion.
3.18.6.4 REF
Selection of the reference signal
This menu is obtained by pressing the REF softkey in the SETUP menu.
Configuration parameter
REFERENCE: Selection of reference frequency source
INTERNAL, EXTERNAL