EB200 Manual Maintenance and Troubleshooting
4052.2000.02 5.3 E-7.1
5.2.2 Error messages
Error message Cause Module
Backup LI-Battery low The lithium backup battery for storing parameters in
the CMOS RAM is dead.
LI-battery
DC Converter defective The DC/DC converter indicates an error. A11
DSP IF Section defective The IF section (EB200Z1) indicates an error. A8
Front Panel defective The front panel control unit (EB200F1) indicates an
error.
A3
Frontend defective The standard frontend indicates an error. A7
Frontend1 defective The standard frontend indicates an error. A7
Frontend2 defective The standard frontend indicates an error. A7
IF Panorama defective The IF panorama module (EB200SU) indicates an
error. The EB200SU is optional.
A9
IF Prefilter narrow defective The IF section (EB200Z1) indicates an error. A8
IF Prefilter wide defective The IF section (EB200Z1) indicates an error. A8
IF Section defective The IF section (EB200Z1) indicates an error. A8
Preselector 20..80 MHz defective The preselection (EB200V1) indicates an error. A6
Preselector 80..200 MHz defective The preselection (EB200V1) indicates an error. A6
Preselector 200..650 MHz defective The preselection (EB200V1) indicates an error. A6
Preselector 650..1500 MHz defective The preselection (EB200V1) indicates an error. A6
Preselector 1500..3000 MHz defective The preselection (EB200V1) indicates an error. A6
Preselector defective The preselection (EB200V1) indicates an error. A6
Remote Interface defective The remote control interface (eg EB200R2) indicates
an error.
A12
Testgenerator defective The preselection (EB200V1) indicates an error. A6