EasyManua.ls Logo

R&S EB200 - Diagnostic Subsystem

R&S EB200
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EB200 Manual DIAGnostic subsystem
4052.2000.02 4.24 E-7
4.5.5 DIAGnostic subsystem
DIAGnostic[:SERVice]
. :INFO
. . :SDATe<numeric_suffix>?
Query of software-generation date
If a module is not available, a zero strings ("") is returned and the error message HW MISSING will be
generated.
Parameters:
The processor is selected via the <numeric suffix>:
1 or no <numeric suffix> main processor (EB200P1)
2 DSP IF Section (EB200Z1)
3 DSP IF Panorama (EB200SU)
4 Front Panel Control Unit (EB200F1)
Result:
<year>,<month>,<day>
<year> = 1900 to
<month> = 1 to 12
<day> = 1 to 31
Example:
DIAGnostic:INFO:SDATe1? -> 1998,10,2
. . :SVERsion<numeric_suffix>?
Query of software version
If a module is not available, a zero string ("") is returned and the error message HW MISSING will be
generated.
Parameters:
The parameter is selected via the <numeric suffix>:
1 or no <numeric suffix> main processor (EB200P1)
2 DSP IF Section (EB200Z1)
3 DSP IF Panorama (EB200SU)
4 Front Panel Control Unit (EB200F1)
5 DC/DC Converter (EB200 DC)
Result:
Software version and identification number of software in format Vxx.yy-aaaa.bbbb.cc (also see *IDN?)
Note:
The query with <numeric suffix> = 5 (DC/DC converter controller) brings up only the version number
without the stock number.
Example:
DIAGnostic:INFO:SVERsion1? -> V01.00-4052.4654.00

Table of Contents