EB200 Manual INPut subsystem
4052.2000.02 4.38 E-7
4.5.9 INPut subsystem
INPut
. :ATTenuation
. . :AUTO <Boolean>
Setting attenuation so that the best dynamic range is obtained; explicit switch on/off of attenuator sets
AUTO to OFF
Parameters:
ON attenuation is coupled to input-signal strength
OFF attenuation is manually switched
*RST state:
ON
Example:
INPut:ATTenuation:AUTO ON
. . :AUTO?
Query of the automatically attenuation setting
Parameters:
none
Result:
Attenuation is automatically switched 1
Attenuation is manually switched 0
Example:
INPut:ATTenuation:AUTO? -> 1
. . :STATe <Boolean>
Switch on/off of input attenuator
Parameters:
ON attenuator on
OFF attenuator off
*RST state:
level-dependent (because of INPut:ATTenuation:AUTO ON after *RST)
Example:
INPut:ATTenuation:STATe ON