EB200 Manual Remote control
4052.2000.02 4.4 E-7
Device-specific commands
Hierarchy: Device-specific commands are of hierarchical structure (see Fig. 4-1).
The different levels are represented by combined headers. Headers of
the highest level (root level) have only one keyword. This keyword
denotes a complete command system.
Example: SENSe
This keyword denotes the command system
SENSe.
For commands of lower levels, the complete path has to be specified,
starting on the left with the highest level, the individual keywords being
separated by a colon ":".
Example:
SENSe:FREQuency:STARt 118 MHz
This command lies in the third level of the SENSe system. It sets the
starting frequency of a scan to 118 MHz.
MODE
SENSe
DETector BWIDth
FREQuency
STOP
FIXed
STEP
AFC
STARt
Fig. 4-1: Tree structure of the SCPI command system using the SENSe system