- 23 - V08 en, SCC
To use the following functions connect a USB Stick to the USB interface
PIn - Load programs from USB Stick onto unit (Program In)
Pout - Load programs from unit onto USB Stick (Program out)
Programs can not be interchanged from SCC or SCC_WE to CM_P and vice versa.
Now set mode switch to Prog/Start and select desired additional program with temperature dial.
Import (Pin):
Should no „progs.xml“ le exist on the USB stick, Pin is blinking (Import not possible, Start key without function).
Should a „progs.xml“ le exist on the USB stick, Pin is showing steady. Import of programs is started by pressing
Start/Prog key. During the import time the Prog/Start-LED is blinking.
Export (Pout):
In case a „progs.xml“ le already exists on the USB stick, Pout is blinking;
Note: Pressing Start key now would overwrite the existing program le!
If Pout is showing steady the programs can be downloaded by pressing Start key. During the download process
the Prog/Start-LED is blinking.
Sout - Copy Service Data to stick
Hout - Copy HACCP Data to stick
As soon as the Start key is pressed, download starts and a LED is circling in the time display.
Program Lock
Select any program number, press timer key and set time to 110 min. Keep timer key pressed and press Prog/
Start key, “P” (Program Lock) is displayed.
When now selecting Prog/Start, “P---” is displayed for 2 seconds.
(Deactivation with same procedure.)
ESG - Empty Steam Generator manually (only with open door)
Close water tap
Press Start - SC pump runs for 45 seconds
°C°F - Setting °C >=< °F
Press Start - display changes from °C to °F or vice versa
rtc - (real time clock) Setting of date and time for HACCP protocol
Conrm the individual settings of hour, minute etc by pressing the START key.
Ethernet connection
Setting IP address: (only possible when Ethernet PCB is installed)
Select IP 1 for rst block. Set block number with timer pot. Press Prog/Start to conrm. Select IP2 with tempera-
ture dial etc.
Setting Gateway Address:
Aer entering IP 4 the display will switch over to GAt 1 automatically. Set block number with timer pot. Press
Prog/Start to conrm. Select GAt 2 with temperature dial etc.
Setting Subnet address:
Aer entering GAt 4 the display will switch over to Sub 1 automatically. Set block number with timer pot. Press
Prog/Start to conrm. Select Sub2 with temperature dial etc.
Additional function

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational CombiMaster Plus CMP and is the answer not in the manual?

Rational CombiMaster Plus CMP Specifications

General IconGeneral
BrandRational
ModelCombiMaster Plus CMP
CategoryCommercial Food Equipment
LanguageEnglish

Related product manuals