V08 en, SCC - 48 -
When to do which action?
1. Self test
2. Manual calibration
3. Flue gas analysis (gas units)
4. Descaling and Setting volume steam generator (aer descaling)
5. Soware update
6. Checking / setting gas type
SCC / CM_P - When to do which action?
SCC_WE CM_P
Aer unit installation
» Self test
» Soware update
» Gas units: Check gas type
» Gas units: ue gas analysis
» Self test
» Soware update
» Gas units: Check gas type
» Gas units: ue gas analysis
Aer Self test
» Soware update
» Gas units: ue gas analysis
» Soware update
» Gas units: ue gas analysis
Aer PCB change Soware update » Soware update
without EEPROM
» Self test
» Flue gas analysis
Aer SD recovery
» Self test
» Gas units: ue gas analysis
Aer EEPROM repair
» Gas units: Check gas type
» Self test
» Gas units: ue gas analysis
During Customer visit Soware update Soware update
During maintenance Gas units: ue gas analysis Gas units: ue gas analysis
» Aer changing gas type
» Aer changing gas burner, electrode
» Aer changing gas valve
Gas units: ue gas analysis Gas units: ue gas analysis
» Aer changing P1
» Aer changing B4
» Aer changing air bae
» Aer disassembly motor / fan wheel /
gasket
» Aer installation of UltraVent at a later time
» Aer removing UltraVent
» Aer installing the unit as the lower unit of a
Combi Duo at a later time.
» Customer complaints because of uneven
cooking results
Manual calibration Manual calibration
Aer installation or removal of an UltraVent
at a later time
Gas units: ue gas analysis Gas units: ue gas analysis
Aer a second Self test (e.g. aer SD repair) Manual descaling of steam gen-
erator followed by press RESET
volume steam generator aer
manual descaling