V08 en, SCC - 32 -
Self test
The unit will run an automatic Self Test rou-
tine aer installation.
The self test comprises a component test, hu-
midity calibration, determination of the boiling
point and volume setting of the steam genera-
tor (SCC only).
Remove all accessories, packing material and
fastening aids from the cabinet.
To start the self test the unit (B1, B2 and B4)
must be below 40°C (104°F). Place a closed
at GN container face down in front of each
fan wheel.
The self test must be completed and can not
be skipped!
Humidity calibration is part of the self test
Dierent food items cook best at their specic humidity level and specic temperature.
Vegetables are steamed, bread is baked in dry heat and roast is cooked at a specic humidity and mostly above
100°C (212°F)
To be able to achieve this task the unit must have stored specic pressure values for cold and dry, steam and com-
bination conditions. These values are stored on the PCB and SD Card.
Self test and humidity calibration is broken down into many dierent steps.
During humidity calibration the dierential pressure sensor P1 determines pressure values at all fan speeds and all
directions.
cold/dry steam combination
Boiling point
200
Self test - Humidity calibration
Selest
Component
test
Boiling
point
calculation
Humidity
calibration
Manual humid-
ity calibration
Needed
when changing:
Motor
Fan wheel
Air baffle
P1, B4
UltraVent
Combi Duo
Sowater:
7°dH, 12,5°F, 8,7°E, 125ppm, 1,25 mmol/l
Selfttest
To determine the optimum number of
cleaner and rinse aid tablets, please specify
whether the unit is connected to normal
water or so water. Please press the ap-
propriate button
Unit is connected to so water
(up to 8,75° e)
Unit is connected to normal water
(over 8,75° e)
Next
Seltest
Your SCC will carry out an automatic
self test and adjust itself perfectly to
the set-up conditions and the altitude.
Selfttest
Your SCC will carry out an automatic
self test and adjust itself perfectly to
the set-up conditions and the altitude.
P1
step 100 - 131
step 301 - 332
step 210 - 241

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational CombiMaster Plus CMP and is the answer not in the manual?

Rational CombiMaster Plus CMP Specifications

General IconGeneral
BrandRational
ModelCombiMaster Plus CMP
CategoryCommercial Food Equipment
LanguageEnglish

Related product manuals