V08 en, SCC - 46 -
Format of unit service data
Startup report version (2)....: 20141029144122 Soware update to version 06.00.05
Startup report version (3)....: 20160203083546 Soware update to version 06.00.06
Startup report version (4)....: 20160322121432 Soware update to version 06.00.08
Date and Time................ .: 20120515092835
Startup Date and Time.........: undef Unit type.....................: SCC_62
Energy type........... ........: G
Unit Serial number......... ...: G62SH12022208034 Soware version..............: SCC-06-00-08
Script version................:
SW-update Date and Time.......: undef CPU-Board Revision............: 0506
CPU-Board Serial number.......: 25233859
CPU-Board Manufacturing date..: 2011-05-19 17:57:58 Burner Control 0 SW-version...:
Burner Control 1 SW-version...: Language......................: german
Basic Settings
--------------
Drain Valve time0......................................: 8.7 s
Drain Valve time1......................................: 26.1 s
Gas type................................... ............: G20
Altitude pressure sensor............................: 255 (Electric: always -5000)
Altitude boiling point.......................... .......: 648
Diagnostic-Real Time Data-Sensors act max lim Time Stamp dimension
Cabinet B1.............................: 26.46 307.85 350 C
Quenching B2...........................: 21.40 95.18 300 C
Temperature PCB........................: 35.34 81.11 80 20120514130736 C
Diagnostic-Real Time Data-Clima Status Dry Wet Combi dimension
Clima Status 1-L.......................: 500 152.8 171.7 185.9 kPa
Clima Status 1-R.......................: 500 164.3 187.8 199.3 kPa
Clima Flap Y5..........................: CLOSE
Clima Output P1........................: 0.00 V
Clima Humidity.........................: 4.00 %
Diagnostic-Water, CJ/Care Motor/Switch Status Status Status dimension
Filling solenoid Y1....................: OFF
Volume Steam Generator (Norm Fill Calc): 5.48 5.22 4.38 l
CleanJet Pump M6........................: OFF
Door Contact S3........................: OFF
.......................................:
Diagnostic-Service History-SCC First time Quantity Last time
Service 10.............................: 20111210215318 5 20120418135651
Service 34.2...........................: 20111213084631 5 20120423131943
.......................................:
Diagnostic-Service History-Gas Top-Box First time Quantity Last time
14.....................................: 20120210145254 3 20120516135457
Diagnostic-Running Times-Components Value dim
Door Opening S3........................: 585
Ball Valve Openings S12................: 1381
Diagnostic-Running Times-Modes Value dim
Hot Air Mode...........................: 192 h
medium.................................: 0 h
medium with steam generator descale (2): 0 0 h
medium w/o steam generator descale (2).: 0 0 h

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational CombiMaster Plus CMP and is the answer not in the manual?

Rational CombiMaster Plus CMP Specifications

General IconGeneral
BrandRational
ModelCombiMaster Plus CMP
CategoryCommercial Food Equipment
LanguageEnglish

Related product manuals