V08 en, SCC - 62 -
Cleanjet CMP
?
?
20 min
Reinigung - Cleaning - Nettoyage - Limpieza
mycie - Мойка - 洗浄
- 清洗
Abbruch - Abort - Interruption - Abortar
przerwanie - Прервано - 中止
- 中断
?
Cool down unit below 60°C (140°F)
Select desired cleaning program
Insert required number of cleaner and rinse tab into air bae basket
Close cabinet door
Press Prog/Clean/Start button
CleanJet Abort
Aborting Cleanjet program before water is pumped into the cabinet:
Switch unit o and on again
“STOP” and “tab out” is displayed
remove all chemical from the cabinet
Close the cabinet door
“rinse cab” is displayed
Wash out the cabinet with the hand shower, Close the door
Cooking is possible
Aborting Cleanjet program aer water was pumped into the cabinet:
Switch unit o and on again
“STOP” and “tab out” is displayed
remove all chemical from the cabinet
Close the cabinet door
“rinse” is displayed (00:20 min)
End is displayed
Cooking is possible
CleanJet
All CM_P units 60 - 202 with index I are build with CleanJet function (like SCC 2004-2008)
(drain valve and cleanjet pump, no Care function).
Chemicals to be used are:
Cleaner tab 56.00.210
Rinse tab 56.00.211
The following CleanJet programs are available:
CLE1 03:30 hrs
CLE2 02:30 hrs
CLE3 00:40 hrs (intermediate cleaning)
The cleanjet function can be disabled in basic settings SE23. ACLn Automatic Cleaning ON / OFF
When a USB stick is connected to the PCB, the cleanjet process can be logged by:
SE24 ACLo Automatic Cleaning Log ON / OFF
Scale detection system:
All CM_P units 60 - 202 are equipped with a scale detection system for the steam generator. This system is soware
based (without CDS sensor).
In case the steam generator is having appr. 20% of scale, the display will show aer ending of the cleanjet process: :
In basic settings (SE25) the automatic scale detection can be congured: auto - hour - o
Standard is Automatic. The scale detection system can also be switched o (SE25).
Dual water supply:
In case the temperature of the treated water is dierent from the standard water supply, set CdSE (SE25) to hour (xed
hours of steam production - not adjustable)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational CombiMaster Plus CMP and is the answer not in the manual?

Rational CombiMaster Plus CMP Specifications

General IconGeneral
BrandRational
ModelCombiMaster Plus CMP
CategoryCommercial Food Equipment
LanguageEnglish

Related product manuals