- 45 - V08 en, SCC
Download of Service, Info and HACCP data, Battery
Service and HACCP data can be downloaded to any USB stick
SCC
Service Data
All data of diagnostic, running time, basic settings and error history can be downloaded from the unit to USB
stick.
This can be done during an active process or also if the unit is in standby (unit must be switched on).
Connect USB Stick to unit interface.
Press the Service Download key
When the green tick mark is shown, the download is
successful.
HACCP Data (Hazard Analysis of Critical Control Points)
All critical data of the cooking programs like Core temperature, cooking temperature and time are stored as a
reference and proof for safe food production. Theses data are kept for a minimum of 10 days (memory space)
and can be downloaded. The download period can be custom set.
Connect USB Stick to unit interface.
Press the HACCP data download key
When the green tick mark is shown, the download is successful.
Info data
In case of a unknown problem or a customer complaint it is advisable to download also the Info data.
All customer inputs are recorded in this le.
Error reporting:
When reporting an error please restrict the download period of info data and
HACCP data to the time (date) of the error. Download Info data, HACCP and Ser-
vice data, pack the data as a zip le and send to your responsible Rational service
manager.
CM_P
Connect USB Stick to unit interface.
Turn the mode switch to the Prog/Start position and select Sout (Service) or Hout (HACCP) with the
temperature dial.
Press the Prog/Start key to download data.
Battery
The battery (CR 2032) is responsible for the backup of the SRAM and for the HACCP data and time setting.
NOTE: Removing of the battery does not reset any unit error, but will erase HACCP data and time and date set-
ting!
At a voltage of below 2,9V (see Diagnostic) the battery should be changed.
http://bit.ly/data_download

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational CombiMaster Plus CMP and is the answer not in the manual?

Rational CombiMaster Plus CMP Specifications

General IconGeneral
BrandRational
ModelCombiMaster Plus CMP
CategoryCommercial Food Equipment
LanguageEnglish

Related product manuals