- 59 - V08 en, SCC
Cleanjet/CareControl SCC
Using any of the Cleanjet programs: Quick, Save, Medium or Strong will reset the bars of the Display Clean to 1
green bar (starting with soware version 05-00-09).
CleanJet +Care can only be started when the cabinet temperature is below 50°C (122°F).
1) Cleaner Tabs: 56.00.210 - for SCC index E, G, H and index I units
- for CM_P index I units
2) Rinse Tabs: 56.00.211 - only for SCC index E and CM_P index I units
2) Care Tabs: 56.00.562 - only for SCC index G - I units
The use of Rinse tab 56.00.211 in a SCC unit index G - I will lead to a blocked Care
pump and Service 40 error.
The condition of the indication depends on:
the use of the unit
the cleaning behaviour of the customer
the degree of scale in the steam generator (see information CDS).
Display Maintenance status - long term status display
1: very good care - arrow position green
2: medium care - arrow position yellow
3: neglected care - arrow position red
The request for Clean+Care has been neglected several times.
Only regular cleaning will reduce the display to one green bar again.
Display Cleanliness - short term / daily status display
Actual dirt status
1: arrow position green - no cleaning necessary
2: arrow position yellow - CleanJet request will show soon
3: arrow position red - Cleaning urgently required
CleanJet request is dependent on the usage pattern of the unit:
- SCC processes, - manual modes, - cooking programs, - duration, - temperatures
1 2 3
For demonstration of CleanJet+Care to the customer switch the unit rst to Demo
mode followed by switching o and on.
Now you can demonstrate the behaviour of the Maintenance and Cleanliness bar
by pressing on the individual bars.
In case an error 27, 40-44 is existing, Cleanjet*Care can not be started.
(ref. to error messages). Aer repair of 40 - 44, 110-120 a Rinse program (not rinse without tabs) or
full clean program must be run before another cleaning cycle is possible again. With soware ver-
sion 07-00-08 reset error by pressing Function test CleanJet in Service level.
In case an error 110 or 120 is existing, only an abort cycle of 27 minutes is oered and must be run
successfully before the unit can be used again.
Cleanjet programs: Each Cleanjet program starts with a components test
Rinse without tabs: Fresh water without chemical is pumped by M6 through the cabinet.
Rinse: Care chemical is pumped by M12 via the steam generator into the control
box and by M6 through the cabinet
Interim cleaning: Cleaner chemical is pumped through the cabinet by M6
Light, Safe, Medium, Strong: Cleaner chemical is pumped through the cabinet by M6. Aer that Care
chemical is pumped by M12 into the steam generator for descaling and part
of it into the control box and by M6 through the cabinet
Programs have dierent duration.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational CombiMaster Plus CMP and is the answer not in the manual?

Rational CombiMaster Plus CMP Specifications

General IconGeneral
BrandRational
ModelCombiMaster Plus CMP
CategoryCommercial Food Equipment
LanguageEnglish

Related product manuals