Page #47 background imageLoading...
Page #47 background image
- 47 - V08 en, SCC
Format of HACCP data
HACCP-Data are shown in the following format:
*** H A C C P ***
;
; Ch-nr. >>210<< = batch number
(number of stored cooking processes)
; Type >>SCC_101<< = unit type
; Serial nr.>>G11SH151224923212<< = Serial number of the unit
; Version >>SCC - (s/o/C)<< = Soware version of the unit
(„C“ indicates, delay of CleanJet request is activated
Only chain units:
„s“ or „o“ shows unit ran on
(s) Supervisor- or (o) Operator mode.)
; Time >>2011.09.20 12:27:26<< = Starting date and time of the cooking process
; Progr. >>Roast<< = Program name
(if „>><<“ appears, manual mode was used)
; #1 : Gartemp. / cabinet temp.
; #2 : Kerntemp. Soll / core temp. target
; #3 : Kerntemp / core temp.
; #4 : Zeit (Std:Min:Sek) / time (h:min:sec)
; #5 : Temp. Einheit / temp. unit
; #6 : Energie Opt. / energy opt.
; #7 : Energie 1/2 / energy 1/2
; #1 #2 #3 #4 #5 #6 #7
Mode HOT AIR
27 - 26 000:00:00 C 0 -
; Door closed 000:00:00
27 - 26 000:00:01 C 0 -
; Mode STEAM
27 - 26 000:00:03 C 0 -
30 - 28 000:01:00 C 0 -
; Mode COMBI
30 - 28 000:01:04 C 0 -
106 - 60 000:02:00 C 0 -
126 - 103 000:03:00 C 0 -
170 - 140 000:04:00 C 0 -
160 - 150 000:05:00 C 0 -
159 - 155 000:06:00 C 0 -
170 - 162 000:07:00 C 0 -
162 - 162 000:08:00 C 0 -
165 - 161 000:09:00 C 0 -
161 - 161 000:10:00 C 0 -
; end 000:11:00 ; end = End of cooking process
B) Additional indications:
Progr. >>SCC - Universal Roast<< = Indication of selected SCC process
Progr. >>SCC - ~ pork<< = Copied SCC process with new name
Door opened or Door closed = during cooking process
Start (power failed) = Power failure longer than 15 minutes
end (HOME) = Process terminated with Home key
end (RETURN) = Process terminated with arrow back key
end (ERROR) = Process terminated because of error
start ELC = ELC Process started
restart (POWER) = restart aer switching o or power fail
end = Process nished

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational CombiMaster Plus CMP and is the answer not in the manual?

Rational CombiMaster Plus CMP Specifications

General IconGeneral
BrandRational
ModelCombiMaster Plus CMP
CategoryCommercial Food Equipment
LanguageEnglish

Related product manuals