- 71 - V08 en, SCC
Basic settings - Content
Water Status Factory Setting, Detected
values
CDS sensor 1000 1000
Volume steam generator new
aer manual descaling
XX l
Volume steam generator new af-
ter steam generator replacement
XX l
SC pump: set pump duration X sec
SC pump: mode Continuous or Puls
SC pump: set interval time X min
Control thermocouple temp.
hot air
XX°C
Control thermocouple temp.
steam
XX°C
Cleanjet / Care
Drain valve Start t1 XX s, t2 xx s
Steam corrosion control "on" or "o"
So water „on“ or „o“
Care Control Reset
Phone numbers, UltraVent, Self
test
Service Phone Setting edit
Chef line phone setting edit
Deactivate UltraVent deact
Self test o
Deactivate interior light on - o
Gas system Data
Gas type Nat. H
RPM Correction Self test - P1 cold - Factory
value
Ultravent on / o
Gas blower speed steam Start rpm XXXX (factory XXXX)
Gas blower speed steam Min rpm XXXX (factory XXXX)
Gas blower speed steam Max rpm XXXX (factory XXXX)
Gas blower speed hot air top Start rpm XXXX (factory XXXX)
Gas blower speed hot air top Min rpm XXXX (factory XXXX)
Gas blower speed hot air top Max rpm XXXX (factory XXXX)
Gas blower speed hot air bottom Start rpm XXXX (factory XXXX)
Gas blower speed hot air bottom Min rpm XXXX (factory XXXX)
Gas blower speed hot air bottom Max rpm XXXX (factory XXXX)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational CombiMaster Plus CMP and is the answer not in the manual?

Rational CombiMaster Plus CMP Specifications

General IconGeneral
BrandRational
ModelCombiMaster Plus CMP
CategoryCommercial Food Equipment
LanguageEnglish

Related product manuals