Operation Quantron E 4
54
b) Procedure when spreading with Auto km/h + Stat. kg:
1. Each time you switch on the Quantron E, use the kg button to switch to the
Weigh Quantity menu and weigh the volume of fertiliser using Refill or New
Fertiliser.
See 4.2.3:
Weigh quantity, page 27
2. Press the Enter key.
3. Carry out the fertiliser settings:
Application rate (kg/ha)
Working width (m)
4. Pour the fertiliser in.
The Weigh Quantity window appears in the display.
5. Highlight the action carried out in the display:
Refill: Continue spreading with the same fertiliser. All stored values (flow fac-
tor) are retained.
New fertiliser: Flow factor is reset to 1.0. If necessary, you can enter the re-
quired flow factor value later on.
ESC Quit
6. Press the Enter key.
7. Refer to the fertiliser chart or empirical values for the flow factor and enter it
manually.
8. Press the Start/Stop button.
The spreading starts.
9. After at least 150 kg of fertiliser has been discharged, press the Start/Stop
button.
10. Stop the tractor on a level surface.
The fertiliser spreader must be horizontal.
11. Switch to the Weigh Quantity menu using the kg key.
12. Highlight the Weigh remnant selection field.
13. Press the Enter key.
The quantity discharged is compared with the actual remaining fertiliser
volume in the hopper.
The flow factor is then recalculated accordingly.
14. Specify the flow factor.
To accept the newly calculated flow factor, press the Enter key.
To accept the previously saved flow factor, press the ESC key.