3 Web-based Management
3.7.3.1 Basic Configuration
This page sets Region Name and Revision level of MST configuration Identifiers.
Region Name: a variable length text string of up to 32 octets
Revision level: a 2-octet unsigned integer. It ranges from 0 to 65535.
3.7.3.2 MSTI Configuration
This page sets MSTI ID, MSTI Admin, and Priority for each MST instance.
MSTI ID: MSTI identification, ranging from 0 to 15
MSTI Admin: enable/disable the specified instance
Priority: sets a priority for the specified instance. It is in the range from 0 to 65535; the default
value is 32768
3.7.3.3 Instance MAP
This page maps one or more VLANs into a specific MST instance. One or more VLANs can
be assigned to a spanning-tree instance at a time. The bottom part of this page lists the VLAN
mapping table.