Jabbers The total number of the received packets that are longer than
1518 octets (excluding framing bits, but including FCS octets),
and has either a bad FCS with an integral number of octets (FCS
Error) or a bad FCS with a non-integral number of octets
(Alignment Error).
Collisions The best estimate of the total number of collisions on this Ethernet
segment.
Pkts 64 Octets The total number of received packets, that are 64 octets in length
(excluding framing bits, but including FCS octets), including bad
packets.
Pkts 65 to 127 Octets The total number of received packets, that are between 65 and
127 octets in length inclusive (excluding framing bits, but including
FCS octets), including bad packets.
Pkts 128 to 255 Octets The total number of received packets, that are between 128 and
255 octets in length inclusive (excluding framing bits, but including
FCS octets), including bad packets.
Pkts 256 to 511 Octets The total number of packets, including bad packets, received that
are between 256 and 511 octets in length inclusive (excluding
framing bits, but including FCS octets).
Pkts 512 to 1023 Octets The total number of received packets, that are between 512 and
1023 octets in length inclusive (excluding framing bits, but
including FCS octets), including bad packets.
Pkts 1024 to 1518 Octets The total number of received packets, that are between 102 4 and
1518 octets in length inclusive (excluding framing bits, but
including FCS octets), including bad packets.
Drop Events The total number of events when packets are dropped by the
probe due to lack of resources.
3.10.2 History
3.10.2.1 History control
This page sets a history control entry on each port. And then the port will be sampled with the
specified interval and the specified sample number about its transmitting situation.
Port The Ethernet port for collecting statistics.
Owner The entity that configured this entry and is therefore using the
resources assigned to it.
Sampling interval(s) The data sample time interval of each group. The interval
range is from 1 and 3600(1 hour).