Maintenance
Prior to each use
56
7 Maintenance
Pos: 72 /ZINDEL/Rollref fanlagen/W artung/Wartung vor jeder Benu tzung RF90 @ 1\mod_141206385 0593_13349.doc x @ 14006 @ 2 @ 1
7.1 Prior to each use
Check ropes and lashings.
Check furling sections for external signs of damage.
Check the functioning of manual operation.
Check hydraulic couplings for external signs of damage and leaks.
Pos: 73 /ZINDEL/Rollref fanlagen/W artung/Wartung nach jeder Benu tzung RF90 @ 1\mod_141206445 9247_13349.doc x @ 14007 @ 2 @ 1
7.2 After each use
Notice
Risk of damage to gear through penetration by water
Do not point a pressure washer at the winch handle socket.
Rinse off all parts with fresh water.
Pos: 74 /ZINDEL/Rollref fanlagen/W artung/Jährliche War tung RF90 @ 1\mod_1412064665378_ 13349.docx @ 14008 @ 2 @ 1
7.3 Annual maintenance
The furling system must be dismantled in a shipyard for annual maintenance. See 9 Disassembly.
The following tasks and checks must be carried out within the scope of annual maintenance:
Remove all contaminants and salt deposits.
Check the forestay for damage.
Check the ease of movement of the halyard swivel.
Replace the lashings and shackles.
Polish stainless steel parts.
Pos: 75 /ZINDEL/Rollref fanlagen/W artung/Wartung alle fünf Jahre RF90 @ 1\mod_1412066944245_ 13349.docx @ 14009 @ 2 @ 1
7.4 Every five years
The following parts must be serviced by an authorised service station every five years:
Drive unit with adjuster
Halyard swivel
Addresses of authorised service stations can be found at www.reckmann.com.