RED DSMC OPERATION GUIDE
COPYRIGHT © 2014 RED.COM, INC 955-0020_V5.2, REV-G | 93
SENSOR SYNC MODE
Sensor Sync Mode allows the shutter timing (scan start) to sync to an external signal.
Off: Sensor runs at the current sensor frame rate. This is the default option.
Genlock: Sensor synchronizes with the incoming compatible genlock signal.
MoCo: Each rising edge on the sync input triggers a frame to be captured.
GENLOCK SOURCE
Select a genlock input:
Brain (default)
Rear Module (Pro I/O Module)
BRAIN GPIO
Camera Input: Select one (1) of the following options to configure the input for devices connected to the
SYNC connector on the BRAIN:
‒ Sync In: The camera input is used as a sync-in signal for MoCo.
‒ General Purpose In: Use the Brain GPI In High/Low drop-down menus to map inputs to actions.
Camera Output: Select an options to configure the output for devices connected to the CTRL connector on
the BRAIN:
‒ Sync Out: Provides an output sync signal to act as a shutter start tally.
‒ Recording Indicator Out: Provides a signal when recording is in process.
For more information, go to “Input/Output Connectors” on page 174.
GEN AND SYNC STATUS INDICATORS
The Lower Status Row of the camera display has GEN and SYNC indicators, which change color based on the
current genlock and sync statuses. For more information, go to “System Status Indicators” on page 49.