3) Laser Pointer Calibration
◈ Spindle
1. Fix a material of flat surface on the clamp.
2. Press button to move the tool to the clamp.
3. Press button and go to the expert menu mode.
4. Press button, and when menu appears on the LCD window, then press
and hold button until it beeps (more than 3 seconds) to run the menu.
5. Select the “3. Pointer/Flat” then press and hold button until it beeps (more than 3 seconds) to run the
menu.
6. The tool draws cross (+) lines on the materials and the laser pointer is turned on.
7. Move the laser pointer to the center of the cross by using the direction key. Then
press and hold button.
8. Laser pointer moves closer to the material to accurately calibrate the laser pointer’s origin.
Move the laser pointer to the center of the cross by using the direction key on engraver,
and press and hold the button until it beeps (more than 3 seconds) to confirm that the setting is saved.
◈ Rotation clamp