User Manual Bearing System RT-300
Issue: 2017/06/27 [Rev 1.04.c] Page 40 of 79 12-9-1-0013-9-2-0001-3-1-60
Following setups can be done in the menu BEARING:
Menu
Designation
Meaning
AVERAGING Averaging bearing
value
Adjustment of the depth of the
bearing value memory
COMPENSATION Compensation of
reference direction
Selection of heading compensation
source
MOUNTING Mounting direction
(up / down)
Input of mounting direction
OFFSET Bearing value offset Input of a correcting value (deviation)
for bearing value output
LAST TIME Duration of indication
of last bearing value
Adjustment of bearing value
indication after last bearing
LAST COMP Correction of the
heading in LED-circle
display
Activation / Deactivation of heading
compensation of LED-circle display
(repeat function)
6.2.1.5.1.1 Adjusting Bearing Value Averaging Memory: AVERAGING
Common Remarks:
The bearing system processes about 750 bearing values a
second. Depending on the quality of the received signal (field
strength, modulation), the single bearing results may be varying significantly. The single bearing
values are being averaged with a special algorithm by the DCU´s electronic. The depth of the
value memory (number of used single bearing values) may be adjusted in submenu SETUP -
BEARING - AVERAGING (see Fig. 52).
To be considered:
- the greater the averaging level the greater the depth of memory
- the greater the averaging level the more stable the display
- the greater the averaging level the higher the sensitivity
- the greater the averaging level the more drag error!
So, the adjustment has to be a compromise between a stable display and the drag error.
With a high averaging level the sensitivity becomes a bit better (with deactivated squelch), but
the display is getting rather inert, thus complicating the normal working with the system.
Fig. 52
ATTENTION
Setup adjustments in this menu are influencing the bearing result. Faulty setups
may lead to wrong bearing results, and it may not be possible, to recognize this
error immediately. In case of doubt don´t hesitate to contact the service or the
service hotline of RHOTHETA.