1105 1 Warm Up-Center
[140 to 180 / 160 / 1°C/step]
1105 2 Warm Up-End
1105 3 Standby-Center [140 to 170 / 155 / 1°C/step]
1105 4 Standby-End [140 to 165 / 150 / 1°C/step]
1105 5 Copying-Center
[140 to 185 / 160 / 1°C/step]
1105 6 Copying-End
1105 7 Low Level 2-Center
[0 to 80 / 60 / 1°C/step]
1105 8 Low Level 2-End
1105 9 Thick-Center
[140 to 185 / 175 / 1°C/step]
1105 10 Thick-End
1105 11 Warm Up Low-Center
[140 to 180 / 170 / 1°C/step]
1105 12 Warm Up Low-End
1106 Display Fusing
1106 1 Displays the fusing temperature (center)
1106 2 Displays the fusing temperature (end)
1107*
Fusing Soft Start
Adjusts the number of zero-cross cycles of the fusing lamp AC supply needed to bring the
fusing lamp power to 100% while bringing the lamp up to the standby temperature or while
copying. Increase this value if the machine is experiencing sudden power dropouts (
Fusing Temperature Control).
1107 1 Warm Up Soft Start [0 = 10 cycles / 1 = 20 cycles / 2 = 50 cycles]
1107 2 Other Soft Start [0 = 5 cycles / 1 = 10 cycles / 2 = 20 cycles]
1108* Set-Fusing Start [0 = 1s / 1 = 1.5s / 2 = 2s]
1108 1 Specifies the interval for fusing-temperature control ( Fusing Temperature Control).
1109 Nip Band Check