Fusing/Exit
D017/D018/D019/D020/D084/D085 4-37 SM
Replacement
and
Adjustment
4.7 FUSING/EXIT
Turn off the main power switch and disconnect the power cord before you start any
of the procedures in this section.
4.7.1 FUSING UNIT
Allow time for the unit to cool before doing the following procedure.
1. Release the duplex unit, if it has been installed, and open the right cover.
2. Remove the fusing unit [A] (
x2).