Service Call Conditions
D017/D018/D019/D020/D084/D085 3-40 SM Appendix
823 B
Self-diagnostic error: NIB
[XXXX]: Detailed error code
[6101]
MAC address check sum error
The result of the MAC address check sum does not match the check sum
stored in ROM.
[6104]
PHY IC error
The PHY IC on the controller cannot be correctly recognized.
[6105]
PHY IC loop-back error
An error occurred during the loop-back test for the PHY IC on the controller.
- Replace the controller.
824 D
Self-diagnosis error: Standard NVRAM
The controller cannot recognize the standard NVRAM installed or detects
that the NVRAM is defective.
[1401]
Loose connection
Defective standard NVRAM
Defective controller
Check the standard NVRAM is firmly inserted into the socket.
Replace the NVRAM.
Replace the controller